13 Error Description
Scope
Error Message
Cause
Measure
Camera
MP CAM#4: video
signal ERROR
Wrong number of cam-
eras in setup
Check wheth-
er the correct
number of
cameras has
been entered
for BOP in the
setup.
Check using
the web
browser.
Camera
MP CAM#4: video
signal back o.k
Bad contact at the con-
nection points or BNC
cable is broken / not
connected.
Check for con-
tact issues with
the camera, the
camera BNC
connections
and the cables.
Power
Jun 20 09:12:46 bop
xd
user.err syslog:
(0265:03) uncon-
trolled POWER OFF
or RESTART or HDD
access failure
This error message can
be cause by:
- Unexpected external
power supply disconnec-
tion
- Power supply contact
issues
- BOP system internal
issues
Check whether
the power sup-
ply has been
disconnected
(24V power
supply).
Change BOP
HDD (reformat
it).
Change the
BOP system to
exclude BOP-
related issues.
Power
„uncontrolled POWER-
OFF or RESTART or
HDD access failure
The BOP HDD file sys-
tem has not been
properly closed on shut
down. Terminal 30
without power
Information
only, no
measures re-
quired
USB
Jun 20 11:10:38 bop
xd
daemon.err klogd:
hub.c: connect-
debounce failed, port 1
USB hub sends a com-
munication issue notifi-
cation
Check the con-
tact to the USB
and the con-
nected devices

Table of Contents