1-4 ADS TRITON+ Manual
Sensors
The TRITON+ monitor supports several approved IS sensors that
vary in measurement methodology, redundancy, and other features.
The monitor is approved for accommodating up to two of the same
or different types of IS sensors. Following are the approved IS
sensors:
x AV|Gated Sensor Performs upward ultrasonic depth,
pressure depth, gated velocity, and water temperature
measurements and mounts at the bottom of the pipe under the
flow surface (ADS p/n 8K-CS7-10-35).
x AV|Max Sensor Performs upward ultrasonic depth, pressure
depth, peak velocity, and water temperature measurements and
mounts at or near the bottom of the pipe under the flow surface
(ADS p/n 8K-CS9-10-35).
x Inclinometer Utilizes an integrated accelerometer in a sealed
and intrinsically safe housing to accurately determine state of
flood gate positioning in water control and management
systems (ADS p/n 8K-0528).
x Long Range Depth Sensor Performs downward ultrasonic
depth measurement and air temperature measurements and
mounts within 12 inches (305 mm) of the underside of the
manhole cover (ADS p/n 8K-CS6-C1-10).
z ParaDepth Sensor Performs downward ultrasonic depth
and air temperature measurements and mounts at the top (or
crown) of the pipe above the flow (ADS p/n 8K-CS8-D1-00-
30-IS). It can also be mounted in the manhole using the ADS
Topside Retrieval System (ADS p/n 8000-0597, 8000-0598,
8000-0654).
z ParaFlow Sensor Performs downward ultrasonic depth,
surcharge pressure depth, surface velocity, surcharge velocity
and air temperature measurements and mounts at top (or
crown) of the pipe above the flow (ADS p/n 8K-CS8-V2-10-
30-IS). It can also be mounted in the manhole using the ADS
Topside Retrieval System (ADS p/n 8000-0597, 8000-0598,
8000-0654). ).