EasyManua.ls Logo

ADS TRITON+ - Activating the Monitor

ADS TRITON+
535 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
4-88 ADS TRITON+
®
Manual
Activating the Monitor
Note: ADS recommends the initial TRITON+ monitor
activation be performed in the office prior to installing the
monitor in the field. Attach the wireless antenna before
attempting to connect wirelessly with the TRITON+. Once
the activation is successful, leave the wireless antenna
attached during transport to the field.
After configuring the monitor, activate the monitor to initiate the
flow monitoring process based on the monitor configuration.
Monitor activation involves generating the activation data using the
Qstart
XML
software, downloading this data to the monitor, and
initiating flow data measurement and logging. The activation data
includes relevant portions of the XML and other configuration
parameters necessary to ensure monitoring activities reflect the
specific site conditions and project requirements. The monitor
requires these files and information to properly measure and record
the flow.
Activate the monitor in the following way:
1. Attach the wireless antenna to the monitor.
2. Select the monitor you want to activate from the Location
Name drop-down list in the Monitor section on the ADS
Qstart
XML
dialog.
3. Verify that the configuration parameters and Connect type for
the monitor and monitoring point are correct and make
modifications, as necessary. The initial monitor activation (or
an activation which follows a deactivation) must be performed
using the SERIAL communication.
4. Click on the Activate button in the Functions section.
The computer connects to the monitor and downloads the
appropriate information and files. Once activation is
complete, the status bar reads Activate successful.