Configuration and Activation 4-97
1. Select the monitor for which you want to perform
confirmations from the Location Name field in the Monitor
section on the ADS Qstart
XML
dialog.
2. Select the device with the sensor(s) you want to confirm from
the Devices list.
3. Click on the Confirm button on the Monitoring Point tab.
Qstart
XML
establishes a connection with the monitor and
displays the Confirm Device dialog.
4. Select the point of reference from which to compare manual
depth to the actual sensor readings from the drop-down list in
the Field Measurement section.
DOF Represents the depth of the flow from the bottom of
the pipe to the flow surface.
Air DOF Crown Represents the distance (or range) from
the top (or crown) of the pipe to the flow surface.
Air DOF Bat Represents the distance (or range) from the
ultrasonic depth sensor face (crystal surface) to the flow
surface.
5. Enter the distance measured manually from the bottom of the
pipe to the flow surface in the Depth field or the range from
the pipe crown/sensor face (as applicable) to the flow surface
in the Range field. The measurement perspective depends on
the option selected in step 4. Enter any estimated deviation
corresponding to the measurement in the +/- field.
6. Enter the velocity of the flow measured manually using a
portable velocity meter in the Velocity field.
7. Enter the initials or designation for the field personnel in the
Crew field.
8. As applicable, enter the Velocity Profile information. The
average velocity will be automatically calculated by Qstart
XML
.
9. Enter any information corresponding to the field
measurements, the flow conditions, or location that may be
relevant to the confirmations in the Comments field.