10-14 ADS TRITON+ Manual
Des
cription
Qstart
XML
Entity
Standard Units of
Measure
Registers
Unidepth,
Monitoring Point
1
MP1/UD
Inches
40045
-40046
Velocity with
gain applied,
Monitoring Point
1
MP1/RV1
Feet per Second
40047
-40048
Flow rate based
on QContinuity,
Monitoring Point
1
MP1/FLOW1
Millions of Gallons
per Day
40049
-40050
Flow volume,
Monitoring Point
1
MP1/FLOW_TOTAL
Thousands of
Gallons
40051
-40052
Ultrasonic Depth
from sensor
connected to
Channel 1
CH1/U1
Inches
40053
-40054
Peak Velocity
from Peak
Combo, Velocity
from AV|Gated,
or
Surface
Velocity
from
Surface Combo
CH1/V1 or DV1
Feet per Second
40055
-40056
Pressure Depth
from Peak
Combo
or
AV|Gated sensor
CH1/P1
Inches
40057
-40058
Surcharge Peak
Velocity from the
Surface Combo
Sensor
CH1/PV1
Feet per Second
40059
-40060
Temperature
from the sensor
attached to
Channel 1
CH1/CT1
Fahrenheit
40061
-40062
Unidepth,
Monitoring Point
2
MP2/UD2
Inches
40065
-40066

Table of Contents