11-46 ADS TRITON+ Manual
Problem
Time on the monitor clock is incorrect.
Possible
Causes
PC clock may have been set to the incorrect time when
the monitor was activated.
Monitor clock may be a faulty.
Monitor time zone difference for the PC clock may not
have been set correctly when the monitor was activated.
Possible
Solutions
Verify the time on the PC clock and correct if necessary.
Reactivate the monitor to enable the clock.
Verify the time
zone
setting of the monitor. Correct and
reactivate if ne
cessary.
Collect the data from the monitor and replace monitor if
defective.
Problem
You receive a
Device Time Out message in
Q
start
XML
.
Possible
Cause
Communications may be marginal.
Modem may be defective.
Possible
Solutions
Re
-
attempt communication with monitor. Verify signal
strength. Check a
Qstart
XML
data collect log or check
the Status in
Qstart
XML
. If the signal strength indicated
is less than
-95 (for example: -99), consider re-
orienting
the antenna and/or installing the antenna in a pedestal
above ground.
Contact your regional ADS representative.
Replace the modem if defective.

Table of Contents