11-46 ADS TRITON+ Manual
Time on the monitor clock is incorrect.
PC clock may have been set to the incorrect time when
the monitor was activated.
Monitor clock may be a faulty.
Monitor time zone difference for the PC clock may not
have been set correctly when the monitor was activated.
Verify the time on the PC clock and correct if necessary.
Reactivate the monitor to enable the clock.
zone
setting of the monitor. Correct and
reactivate if ne
cessary.
Collect the data from the monitor and replace monitor if
defective.
Device Time Out message in
start
XML
.
Communications may be marginal.
-
attempt communication with monitor. Verify signal
strength. Check a
Qstart
XML
data collect log or check
the Status in
Qstart
XML
. If the signal strength indicated
is less than
-95 (for example: -99), consider re-
orienting
the antenna and/or installing the antenna in a pedestal
above ground.
Contact your regional ADS representative.
Replace the modem if defective.