A-12 ADS TRITON+ Manual
ParaFlow Sensor
Housing
Polycarbonate shell (PC)/ PEEK, epoxy-filled.
High visibility yellow color.
Dimensions
13.9
inches (353 mm) long x 2.20 inches (56
mm)
wide x 2.
58 inches (65.5 mm) high
Cable
Standard size: 30.0 feet (9.14 m) long x 0.3
0
inches (
7.6
mm) nominal OD, polyurethane jacket
Extension cables available up to 300 feet (91 m)
Operating /
Storage
Temperature
Operating: -4° to 140° F (-20° to 60° C)
Storage:
-4° to 167° F (-20° to 75° C)
Note:
The sensor will not produce accurate
readings when ice is built up on the sensor.
Downward Ultrasonic Depth
Accuracy
0.125 inches (3.2 mm)
Deadband
0
.0 inches (0 mm) from the face of the sensor
Frequency
125 kHz
Range
0
.0 inches (0 mm) to 12.0 feet (3.66 m)
Resolution
0.01 inches (0.25 mm)
Drift
0 inches (0 mm)