2-14 ADS TRITON+ Manual
XIO
External power requires a power source running 9 to 36 volts at 1.2
amperes of peak current. AC power must first come through a
power supply for DC conversion prior to entering the ExPAC.
ADS recommends using a 24-VDC module (ADS, p/n 508293).
DC power can come directly from the power supply, a solar source,
or rechargeable battery to the ExPAC.
Note: ADS offers two versions of the TRITON+ (ADS
p/n 8000-FST-IM-EP-4WW-ATT and 8000-FST-IM-EP-
4WW-VZW) specifically designed for receiving external
DC power that do not include the battery pack. However,
battery-powered TRITON+ monitors (ADS p/n 8000-FST-
IM-4WW-ATT and 8000-FST-IM-4WW-VZW) may be
converted to receive external power using a special kit
available through ADS (p/n 8000-0434-xxx).
Powering the monitor through an external source is particularly
advantageous at a location that requires logging an extensive
amount of data on a short interval and eliminates the periodic need
for battery replacement and disposal.
Refer to Chapter 6, External Power, for more information on
powering a TRITON+ through an external source.