Advent Communications
209298 - DVE5000 Technical Operation Handbook - CL140042 Page 54 of 110
6.3.9 MISC.
By using the up / down arrow keys, highlight MISC and press ENTER key.
This screen will be displayed: -
Default Enc:
- Miscellaeneous -
Lamp Test:
Contrast:
Fault Test:
Lamp Test: Selecting YES initiates a lamp test routine to check all are ok.
Contrast: Press ENTER and adjust the display contrast by using the up / down arrow
keys to change, press ENTER to confirm or ESCAPE to cancel selection.
Default Enc: Select YES to re-boot DVE5000 if instability occurs or after up-grading software.
Fault Test: Select YES to set ‘status relay’ to simulate a failure in the DVE to test redundancy
controls.
PRESS ESCAPE to return up a menu level.
6.3.10 LICENCES
The DVE5000 is capable of many options which need to be enable by a licence code issued
upon payment. Some functions will work but with limited functionality without a licence code. For
example HD formats will function without a licence but the picture will have red lines across it.
By using the up / down arrow keys, highlight LICENCES and press ENTER key.
This screen will be displayed allowing the entry of a licence code issued by the factory.
- Licences -
*****************
Note, entering an invalid code can render the unit inoperable, caution is advised.
PRESS ESCAPE to return up a menu level.