Advent Communications
209298 - DVE5000 Technical Operation Handbook - CL140042 Page 70 of 110
8.6.4 DVE5000 remote command set
Note: All commands are case sensitive and should be entered as described (some
commands are in upper case, some commands are lower case).
*
These settings are not available from the front panel.
These settings are only available if the correct options have been fitted
↔ These settings are dependent on other settings
8.6.5 Remote Unit settings
Command WVBARx
Response RVBARx
Query RVBAR
Response RVBARx
Bars on input video loss
Parameters x – bars on input video loss (0 = Blank, 1 = Bars + Ident)
Command WGOPTx
Response RGOPTx
Query RGOPT
Response RGOPTx
Modulator Output Type
Parameters x – output type (0 = 70MHz, 1 = IQ (LBand))
Command not available
Response not available
Query RUSOF
Response RUSOFxxxxxxxxxx
Modulator Output
Parameters xxxxxxxxxx – software revision
Modulator Output Command not available
Response not available
Query RUSOF
Response RUSOFxxxxxxxxxx
Parameters xxxxxxxxxx – software revision