209298 - DVE5000 Technical Operation Handbook - CL140042 Page 82 of 110
Response RBDELxxxx
Parameters xxxx – delay in uS (in range -41709- +41709)
Command not available
Response not available
Query RBOFF
Response RBOFFxxxx
Audio B Dolby Align
Offset
Parameters xxxx – align offset in uS (in range 0 - +41709)
Command WCSTAx
Response RCSTAx
Query RCSTA
Response RCSTAx
Audio C Standard
Parameters 0= OFF, 1=disabled, 2= Linear PCM, 3=disabled, 4=
Dolby E, 5=disabled
Command WCINPx
Response RCINPx
Query RCINP
Response RCINPx
Audio C Input
Parameters 0= test tone (disabled), 1 = disabled, 2 = SDI Emb 1, 3 =
disabled
Command WCLANx
Response RCLANx
Query RCLAN
Response RCLANx
Audio C Language
Parameters x – language (0=Eng, 1=Spa, 2=Ger, 3=Fre)
Command WCPIDxxxx
Response RCPIDxxxx
Query RCPID
Response RCPIDxxxx
Audio C PID
Parameters xxxx – audio C PID (in range 32-8190)
Command not available
Response not available
Query RCLOC
Response RCLOCx
Audio C AES/Emb
Lock
Parameters x – audio locked (0=NO, 1=YES)
Command WCTONx
Response RCTONx
Query RCTON
Response RCTONx
Audio C Test Tone
Parameters x – test tone (0=OFF, 1=800Hz)