Parameters x – language (0=Eng, 1=Spa, 2=Ger, 3=Fre)
Command WDPIDxxxx
Response RDPIDxxxx
Query RDPID
Response RDPIDxxxx
Audio D PID
Parameters xxxx – audio D PID (in range 32-8190)
Command not available
Response not available
Query RDLOC
Response RDLOCx
Audio D AES/Emb
Lock
Parameters x – audio locked (0=NO, 1=YES)
Command WDTONx
Response RDTONx
Query RDTON
Response RDTONx
Audio D Test Tone
Parameters x – test tone (0=OFF, 1=800Hz)
Command WDAUTx
Response RDAUTx
Query RDAUT
Response RDAUTx
Audio D Dolby Auto-
Align
Parameters x – auto align (0=OFF, 1=ON)
Command not available
Response not available
Query RDDOL
Response RDDOLx
Audio D Dolby Status
Parameters x – Dolby audio status (0=unlocked, 1=locked)
Command WDDELxxxx
Response RDDELxxxx
Query RDDEL
Response RDDELxxxx
Audio D Dolby Align
Delay
Parameters xxxx – delay in uS (in range -41709- +41709)
Command not available
Response not available
Query RDOFF
Response RDOFFxxxx
Audio D Dolby Align
Offset
Parameters xxxx – align offset in uS (in range 0 - +41709)
Command WTDATx RS232 Data pipe
On/Off
Response RTDATx