Parameters xx.xxxx – symbol rate in Msym, (decimal point allowed)
Command WOGUAx
Response ROGUAx
Query ROGUA
Response ROGUAx
OFDM Guard Interval
Parameters x – guard interval (0= 1/32, 1= 1/16, 2= 1/8, 3= ¼)
Command WOFECx
Response ROFECx
Query ROFEC
Response ROFECx
FEC
Parameters x – FEC (0 = ½, 1 = 2/3, 2 = ¾, 3 = 5/6, 4 = 7/8)
Command WOPOLx
Response ROPOLx
Query ROPOL
Response ROPOLx
Modulation polarity
Parameters x – polarity (0=normal, 1=inverted)
Command WOWIDx
Response ROWIDx
Query ROWID
Response ROWIDx
OFDM Bandwidth
Parameters x – bandwidth (0=6MHz, 1=7MHz, 2=8MHz)
Command WOROLx
Response ROWIDx
Query ROROL
Response ROWIDx
Modulation roll off
factor*
Parameters x – roll off (0=35% (0.35), 1=25% (0.25), 2=20% (0.2))
Command WGMODx
Response RGMODx
Query RGMOD
Response RGMODx
Output type
Parameters x – output type (0 = ASI, 1 = DVB-T
, 2 = DVB-S, 3 =
dummy, 4 = DVB-S2)