4349B
SENSe
Subsystem
Note
This
command
sets
[SENSe:]:CORRection[:STATe]
ON
,
which
enables
the
correction
function.
The
*RST
,
or
:SYSTem:PRESet
commands clear
the
correction
data.
[:SENSe]:CORRection:D
A
T
A
f
1
j
2
j
3
j
4
g
?
OFFSet
Returns
the
OPEN
correction
data
(DC
current
measurement
value).
(query
only)
Query
response
is
a
numeric
value
in
<
NR3
>
format.
[:SENSe]:CORRection:D
AT
A
f
1
j
2
j
3
j
4
g
?
SCAP
acitance
Returns
the capacitance
measurement data
Cres which
is
taken
in
the
OPEN
correction
and
used
for the
contact check
function. Cres
is
required
to
nd
the
contact
check
eective
range
.
See
Chapter 8
for more
detail. (query
only)
The
capacitance value
Cres
returned
by
this
command
shows
the
total
measurement
system's
stray
capacitance,
including
the
4349B
's
internal
stray
capacitance
.
The
returned
Cres
is
typical data,
and
it
is
not
guaranteed.
Query
response
is
a
numeric
value
in
<
NR3
>
format.
[:SENSe]:CORRection[:ST
A
T
e]
f
ON
j
OFF
j
1
j
0
g
Sets
or
queries
if
the
correction data
is enabled
or
not.
ON
,
1
Correction
data
is
enabled.
OFF
,
0
Correction
function
is
disabled.
Query
response
is
f
1
j
0
g
.
[:SENSe]:CONT
act:DA
T
A
f
1
j
2
j
3
j
4
g
?
Returns
the capacitance
data
at
dut
mesurement.
The
contact
check
function
uses
this
capacitance
data. Refer
to \Reading
the
Limit
Data
of
Contact
Check
Function
"
in
Chapter
2
for
detail. (query
only)
Query
response
is
a
numeric
value
in
<
NR3
>
format.
The
data
is
incorrect
if
the
measurement
range
was
changed
after
dut
measurement.
Note
The
accuracy
of the
capacitance
data
is
not
guaranteed.
[:SENSe]:CONTact:LIMit
f
1
j
2
j
3
j
4
g
?
Returns the contact check limit data. Refer to
\Reading the Limit Data of Contact Check
Function" in Chapter 2 for detail. (query only)
Query response is a numeric value in
<
NR3
>
format.
GPIB Reference 5-21

Table of Contents

Other manuals for Agilent Technologies 4349B

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Agilent Technologies 4349B and is the answer not in the manual?

Agilent Technologies 4349B Specifications

General IconGeneral
BrandAgilent Technologies
Model4349B
CategoryMeasuring Instruments
LanguageEnglish

Related product manuals