6-60 Chapter6
Front-Panel Key Reference
Peak Search
Peak Search
Places a marker on the highest priority peak based upon one of two
criteria:
Max (default) or Param (see Peak Search Param Max under Search
Param below). If Max is the criterion, pressing Peak Search places a
marker on the highest point of the trace excluding the LO feedthrough.
If
Param is the criterion, pressing Peak Search places a marker on the
highest peak of the trace that meets the peak excursion criterion (see
Peak Excursn under Search Param below). If no peak meets the criterion,
the marker is placed at the center of the display, and the error message:
No Peak Found appears (see
System (Local), Show Errors below to
remove the error message). When you preset the analyzer (see
Preset
below), the peak search criterion is set to Max unless you make Param
part of the user preset conditions and select that preset option.
Meas Tools Accesses the following frequently used menu keys which are replicated
here for the user’s convenience.
Peak Search Performs peak search as described above. Key access:
Peak Search, Meas Tools
Next Pk Right Refer to page 6-62. Key access: Peak Search, Meas Tools
Next Pk Left Refer to page 6-62 of this chapter. Key access: Peak
Search, Meas Tools
Delta Refer to page 6-44. Key access: Peak Search, Meas Tools
Mkr → CF Refer to page 6-49. Key access: Peak Search, Meas Tools
Mkr → Ref Lvl Refer to page 6-49. Key access: Peak Search, Meas Tools
Function Accesses the following menu keys. Key Access: Peak
Search, Meas Tools
Band Power
Measures the power in a band specified by the user
within the channel bandwidth. Two markers on the
display indicate the edges of the band. The
measurement can be made on a single sweep or can
continuously update at the end of each sweep. The
center frequency, reference level, channel bandwidth,
and the measurement band must be set by the user.
Key Access:
Peak Search, Meas Tools, Function