Event and Accounting Logs
7705 SAR OS System Management Guide Page 263
Parameters eq | neq | lt | lte | gt | gte — this operator specifies the type of match. Valid operators are listed in the
table below.
severity-level — the ITU severity level number. The following table lists severity levels and
corresponding numbers per ITU standards M.3100 X.733 & X.21 severity levels.
subject
Syntax subject {eq | neq} subject [regexp]
no subject
Context config>log>filter filter-id>entry entry-id>match
Description This command adds an event subject as a match criterion.
The subject is the entity for which the event is reported, such as a port. In this case, the port-id string
would be the subject.
Only one subject command can be entered per event filter entry. When multiple subject commands
are entered, the last command overwrites the previous command.
The no form of the command removes the subject match criterion.
Operator Notes
eq Equal to
neq Not equal to
lt Less than
lte Less than or equal to
gt Greater than
gte Greater than or equal to
Severity Number Severity Level
1 cleared
2 indeterminate (info)
3 critical
4major
5minor
6 warning