9. The tool menu - functions
Whenyouareinthetoolmenu(seesection8),youcanusethetoolsdescribedbelow.Stepbetweenthevarioustool
eldsbypressingtheupordownarrowsymbols.YoucanalwaysleavethetoolmenuwiththeMENUbutton.
1. Arrow symbols
Stepbetweenthevarioustooleldsby
pressingtheupor
downarrowsymbols.Youcanalways
leavethetoolmenuwith
theMENUbutton.
2. Clock
Theclockmustbesetifautomaticnight-
timemodeorautomaticstartistobeused.
If12Vvoltageislost,theclockwillbe
resetandcorrecttimewillnolongerbedis-
played.Thisispreventedwithanoptional
AAbatterybackup.
3. Automatic night-time mode
Thisfunctionisusedwhenyouwantto
programthecentralheatingtoautomati-
callylowerthetemperatureatnightand
raisethetemperatureinthemorning.
4. Starting the boiler automatically
Thisfunctionisusedtostarttheboiler
automaticallyatalaterpointoftime.With
automaticstart,theboilerworksfor24
hoursandthenstops.Afterthat,itrepeats
theautomaticstartonceaweek;atthe
samedayandtime,aslongasthefunction
isactivated.Forautomaticstarttofunction,
theOn/OffbuttonmustbesetintheOFF
position.
5. Constant pump operation
Cont.:Withthisfunctionselectedthepump
ispermanentlyon.
Therm:Withthisfunctionselectedthe
pumpiscontrolledbythepanel/roomsen-
sor.Thisisthenormaloperatingmodefor
heatingthevehicleandobtaininganor-
malsupplyofhotwater.Factorysettingis
Therm.
6. *Pump speed
Thecirculationpump’scapacitycanbe
remotecontrolledfromthepanel.
7. Offset (temperature adjustment)
Usingthisfunction,youcancalibratethe
temperatureonthepanelifyounoticethat
thetemperature(thestabilizedroomtem-
perature)isnotthesameasthetempera-
tureshownonthepanel.Thisalsoapplies
tooutdoortemperature.
8
11 13
10
9
7
4
5
2
1
3
6
12
NOTICE
Functions marked with * indicate that the symbol for the function is displayed on the Control Panel even if
the accessory is not installed!
NOTICE
A pump with remote control must be
installed in order that this function
can be used (see the manual for the
vehicle, boat or building).
NOTICE
This function limits the supply of hot
water, particularly when there is a
low heating requirement.

Table of Contents

Other manuals for Alde Compact 3010

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Alde Compact 3010 and is the answer not in the manual?

Alde Compact 3010 Specifications

General IconGeneral
BrandAlde
ModelCompact 3010
CategoryBoiler
LanguageEnglish

Related product manuals