EasyManua.ls Logo

Allen-Bradley 2094-AC05-MP5 - Verify the Parameter Changes

Allen-Bradley 2094-AC05-MP5
290 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
234 Rockwell Automation Publication 2094-UM001J-EN-P - March 2017
Appendix C DC Common Bus Applications
The save to nonvolatile memory is complete and this confirmation
message dialog box opens.
4. Click OK.
5. Close the DriveExplorer software.
Verify the Parameter Changes
Follow these steps to verify your parameter change was successful.
1. Open your DriveExplorer software.
2. Cycle the drive control power.
3. Reconnect the drive to your DriveExplorer software and read the Add
Bus Cap value just like you did in Set the Additional Bus Capacitance
Parameter on page 232
.
4. Verify the new parameter value.
In this example, the new value is 1780 µF.
5. Close the DriveExplorer software.
TIP Verifying the parameter change is optional.

Table of Contents

Related product manuals