80 Rockwell Automation Publication 7000-UM202D-EN-P - May 2018
Chapter 2 Power Component Definition and Maintenance
7. Place the new resistor bank assembly back into the PowerCage module.
8. Slide the retaining rod into place and push the clips back into place.
9. Connect the leads to the resistor bank
10. Install the PowerCage module as outlined in Removing the PowerCage
Module on page 103.
Replacing Snubber Capacitor
The snubber capacitors are part of the capacitor assembly located behind the
PowerCage module.
1. Remove the PowerCage module (see Removing the PowerCage Module
on page 103).
Note the connection of the leads for correct replacement.
2. Detach the lead located on the top of the capacitor.
Figure 70 - Removal of the PowerCage Module
Push Nuts
Common Snubber
and Sharing Resistor
Connection
Snubber Resistor
Connection
Sharing Resistor
Connection
Push Nuts
Snubber Capacitor
Cathode
Connection
Anode Connection