118 ARX 4
1208531 | 03.07.2012
NOTE The battery poles and terminals must be clean. If they are coated with a
(whitish or greenish) sulfur crust they must be removed and cleaned.
10.1.3 Charging the battery using a battery charger
1 Disconnect the battery.
2 Connect the battery charger.
2.1 Observe the battery charger manufacturer’s manual.
3 Start with the (+) terminal when reconnecting the battery.
NOTE The battery poles and terminals must be clean. If they are coated with a
(whitish or greenish) sulfur crust they must be removed and cleaned.
10.1.4 Long-term storage
If the roller is not in operation for more than two days, the battery must be turned off
at the battery cut-off switch. This reduces the risk of battery discharge.
If no battery cut-off switch is fitted to your roller, remove the negative battery cable
from the battery if a standstill period of more than two weeks is expected.
10.2 Fuses
NOTE Before replacing the fuse, you must identify and remove the cause of the fault.
DANGER
There is danger to life if the roller does not stop in hazardous
situations!
• Fuses and safety switches must never be shorted.
CAUTION
Risk of injury through short circuit and cable fire when hand-
ling electrical parts!
• Always disconnect the power supply when working on the elec-
trical system.