EasyManua.ls Logo

Ammann AV 70 X - Page 133

Ammann AV 70 X
162 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
127AV 70 X
400613A
400181
400613A
400217
MAINTENANCE MANUAL
Remove the cooling circuit drain plug. Let the liquid pour •
down into the vessels set up. The drained amount is ca 15 l
(3,96 gal U.S.).
Check whether pipes within the engine cooling system are •
not damaged, clips missing. Check the radiator condition
whether not damaged, not leaking, and cooling gills not
fouled with impurities. Clean and repair the radiator, if re-
quired.
Clean the cooling circuit:
The process of cleaning the cooling circuit is divided into two
parts.
First part:
Install the drain plug, ll the cooling system with the mix-•
ture of the following ratio: 0,5 kg (1 lb) of sodium carbonate
and 23 l of water, or agents normally available on this base.
When lled, wait for ca 2-3 min until air escapes and the cir-•
cuit gets lled. Max lling rate is 10 l/min (2,6 gal US/min).
Do not close the tank with overpressure plug.•
Start the engine and let it run for 5 minutes for liquid tem-•
perature to reach 82°C (180°F).
Stop the engine, drain the cooling circuit and reinstall the drain
plug.
Inspect cooling circuit tightness and liq-
uid level on water gauge.