4.9 Environmental specicaons
• Cooling air ows from right side to le side.
• Max ambient operang temperature: < 40°C (< 104°F).
• Operang temperature: 0 to +40°C / +32°F to +104°F
• Storage temperature: -40 to +70°C / -40°F to +158°F
• Operang humidity: 10 to 80% (non condensing)
• Input voltage range: 100-240 VAC autosensing, 50/60 Hz
• Typical consumpon: 110 W
4.9
D 15.75’’x W 19’’ x H 3.46’’ with rack mount and handles
D 400 mm x W 483 mm x H 88 mm
D 14.17’’x W 17.3’’ x H 3.46’’ without rack mount and handles
D 360 mm x W 440 mm x H 88 mm
6,3kg / 13.9 lb
(Compable with a Standard 19”
rack, Height = 2 U)
ELECTRICAL SECURITY:
• IEC 60950-1:2005 (2nd Edion); Am 1:2009
• EN 60950-1:2006 + A1:2010 + A11:2009 + A12:2011, CSA C22.2; Naonal Dierences specied in the CB
Test Report
• UL listed (Canada & US)
ELECTROMAGNETIC COMPATIBILITY:
• IEC 61000-3-2 (2009)
• IEC 61000-3-3 (2008)
• CISPR22 (2008)
• CISPR24 (2010)
• FCC Part15 of 2012
• IECS-003 of August 2012
ENVIRONMENT:
• RoHS
• WEEE
USE/TRANSPORT:
• ETS 300 019-2-2: Environmental condions and environmental tests for telecommunicaons equipment ;
Part 2-2 : specicaon of environmental tests ; Transportaon ; Specicaon T 2.3: Public transportaon
• ETS 300 019-2-3: Environmental condions and environmental tests for telecommunicaons equipment ;
Part 2-3 : specicaon of environmental tests ; Staonary use at weather protected locaons ; Specicaon
T 3.1 and T 3.1 E: Temperature-controlled locaons
If your device should lose power unexpectedly, you may lose any unsaved sengs.
For PLS350 and PLS350-3G: