10.4 Troubleshooting
Display Possible cause Action
Out of service
E3 Fill error
Boiler is lling too slowly.
During commissioning the inlet
valve KW1 must have lled the
boiler within 180 seconds.
Check the water pressure, fully open
the water supply tap, check the con-
necting hose for kinks.
Switch the machine off and on again.
E5 Brewer error
Brewer does not run to BREW
position (closed) during brewing
proces. Detected by brewer switch
1 (right).
Check whether the brewer is properly
positioned in the motor unit. Check
brewer switch 1 & brewer lever right
for correct operation in the service
menu 2.7 Hardware test
E6 Boiler temperature
Temperatuur sensor measures a
temperature over 105°C
Check the water supply for air.
Check the temperature sensor
operation in the service menu 2.7
Hardware test
Check whether the boil-dry protection
was activated. Reset as necessary.
E7 Brewer motor error
Brewer motor has stalled.
Brewer motor output overloaded
(current too high). The control has
disabled the output.
Clean the brewer with the brush.
Switch the machine off and on again.
Check the ground coffee volume
(grams). Switch the machine off and
on again.
E8 Mixer 2 error
Mixer 2 motor stalled.
Mixer 2 motor output(s) overloaded
(current too high). The control has
disabled the output.
Check whether mixer 2 is contami-
nated or incorrectly mounted. Clean
and/or check whether the rotor turns
freely.
Switch the machine off and on again.
E10 Valve error
Valve output(s) overloaded (current
too high). The control has disabled
the output.
Check the valves and wiring for short
circuits. Switch the machine off and
on again.
E11 Ingredient motor
error
Ingredient motor(s) stalled.
Ingredient motor output(s) overloa-
ded (current too high). The control
has disabled the output.
Check the operation of the drive
motors in the service menu 2.7 Hard-
ware test. Empty the canister(s) and
clean thoroughly.
Switch the machine off and on again.
E13 Mixer group error
Brewer and Mixer output group
overloaded (current too high). The
control has disabled the output.
Carry out the checks as specied for
E7 and E8. Switch the machine off
and on again.