WARNING
• During maintenance activities, remain with the machine.
• When de-scaling, always follow the instructions for the de-scaling agent used.
• It is advisable to wear safety glasses and protective gloves when de-scaling.
• After de-scaling, let the machine complete at least three cycles.
• Wash your hands thoroughly after de-scaling.
• The machine must never be immersed in or sprayed with water.
WARNING
• Pressurised hot water! Do not remove components like valves, couplings,
plugs and hoses before depressurise the boiler system.
6.5 De-scaling instructions
Animo supplies a descaling agent in the following quantities:
• Descaling agent 48x 50 g sachets art. no. 49007
• Descaling agent 1 kg can art. no. 00009
Time required, agents and tools:
• Time: approx. 45 min.
• Animo Descaling Agent
• Drip tray of approx. 1.5 L
• Crosshead screwdriver
• Service kit [art. no. 1001365]
(measurement beaker, hose, manometer)
Descaling
1. Start the descaling programme. Service menu /
2.15 Descale and follow the instructions on the display.
2. Close the door and place an empty bucket under
both outlets.
Descaling Descaling
Place empty container
Press enter (v)
Stop? Press x
Boiler
depressurising
moment please
3. Prepare 2 litre de-scaler solution. Read the warnings
and instructions for the Animo de-scaling agent rst.