74
OptiBean /OptiBean XL
2015/09 Rev. 1.2
4. Remove the back and connect the suction tube to
the tee of the ow meter (remove plug).
Descaling
Place suction tube
in descaler solution
Press enter (v)
5.
The rst acid solution (approx. 1 litre) is pumped into the
boiler and heated. A soaking period of 300 sec. follows*.
Descaling Descaling
Pumping solution
through system
Moment please
boiler temperature
is increased (...C)
Descaling
Moment please
Soaking: 300 sec.
6. Then for 12 seconds the second acid solution
(approx. 1 litre)
is pumped through each of the
dispensing valves. The fresh acid solution is now
heated in the boiler again and a soaking period of
600 seconds follows*.
Descaling Descaling
Pumping solution
through system
Moment please
boiler temperature
is increased (...C)
Descaling
Moment please
Soaking: 600 sec.
* soaking periods can be skipped by pressing the
x-button.