75
2015/09 Rev. 1.2
EN
OptiBean /OptiBean XL
7. After the soaking interval, the suction hose must be
removed and the plug retted.
Descaling
Remove hose
Place stop
Place empty container
Press enter (v)
8. The boiler is ushed (6 times*) with fresh water.
In between, empty and secure the drip tray.
Descaling Descaling
Flushing
Moment please
6x
boiler temperature
is increased (...C)
Descaling
Place empty
container
Press enter (v)
9. Reset after descaling the service boiler signal in the
service menu:
2.6Serviceboiler

└──2.6.02ResetServicecounter
10. The machine is now ready for use again.
Always check if no de-scaler solution stayed
behind in the heating system. Draw some hot
water and mix some coffee milk through it.
If the milk curdle, additional ushing of the heating
system is required.