7. After the soaking interval, the suction hose must be
removed and the plug retted.
Descaling
Remove hose
Place stop
Place empty container
Press enter (v)
8. The boiler is ushed (6 times*) with fresh water.
In between, empty and secure the drip tray.
Descaling Descaling
Flushing
Moment please
6x
boiler temperature
is increased (...C)
Descaling
Place empty
container
Press enter (v)
9. Reset after descaling the service boiler signal in the
service menu:
2.6Serviceboiler
│
└──2.6.02ResetServicecounter
10. The machine is now ready for use again.
Always check if no de-scaler solution stayed
behind in the heating system. Draw some hot
water and mix some coffee milk through it.
If the milk curdle, additional ushing of the heating
system is required.