OptiBean /OptiBean XL
Display Possible cause Action
Out of service
E24 brewer error
Brewer schakelaars komen niet
in de juiste positie tijdens het zet-
proces. Gedetecteerd door brewer
schakelaar 2 (links)
Controleer of brewer goed in motor
unit is geplaatst. Controleer brewer
schakelaar 2 & brewer hendel links
op juiste werking in het servicemenu
2.7 Hardware test
E25 ow meter error
Inlet valve is electrically open but
the ow meter does not register a
water ow.
The water pressure is low or the
water tank (stand alone set) is
empty.
Check the water pressure, fully open
the water supply tap, check the con-
necting hose for kinks. Check the
operation of the inlet valve and ow
meter. Switch the machine off and on
again.
Check after which recipe the error
occurs and check if dispensing valve
functions which belongs to the recipe.
DV1 brewer, DV2 mixer, DV4 hot
water recipe. Replace if necessary.
Switch the machine off and on again.
E26 Low temperature
Temperatuur sensor measures a
boiler temperature below 0°C
Boiler and/or NTC sensor is below
-0°C. Let the machine warm up to
room temperature.
E27 NTC short circuit
Temperatuur sensor measure a
temperature higher than 125°C or
has a short circuit
Boiler over heated, rst let the boiler
cool down. Check if dry-boil protec-
tion was triggered.
Check the NTC sensor and wiring /
connection.
E28 NTC not detected
Temperatuur sensor is not
detected.
Check the NTC sensor and wiring /
connection.