General Information 1-3 Calibration and Verification
Site Master User Guide PN: 10580-00252 Rev. K 1-3
Available Options
Available options for the Site Master are shown in Table 1-2.
1. Requires External Power Sensor.
2. Requires Option 31.
1-3 Calibration and Verification
Anritsu recommends annual calibration and performance verification by local Anritsu
service centers. The Cable and Antenna Analyzer mode requires calibration standards for
OPEN, SHORT, and LOAD (OSL) or InstaCal module, which are sold separately.
The Site Master is self-calibrating and there are no field-adjustable components. The OSL
calibration components are crucial to the integrity of the calibration. As a result, they must be
verified periodically to ensure performance conformity. This is especially important if the
OSL calibration components have been accidentally dropped or over-torqued.
Contact information for Anritsu Service Centers is available at:
http://www.anritsu.com/contact-us
Table 1-2. Available Options
S331E S332E S361E S362E Description
S331E-0010 S332E-0010 S361E-0010 S362E-0010
Bias-Tee (Requires Option 21 on
S331E and S361E)
S331E-0019 S332E-0019 S361E-0019 S362E-0019 High-Accuracy Power Meter
(1)
S331E-0021 S332E-0021 S361E-0021 S362E-0021 2-Port Transmission Measurement
S332E-0025 S362E-0025 Interference Analyzer
(2)
S332E-0027 S362E-0027 Channel Scanner
S332E-0028 S362E-0028
C/W Signal Generator (Requires
CW Signal Generator Kit)
S332E-0029 S362E-0029 Power Meter
S331E-0031 S332E-0031 S361E-0031 S362E-0031
GPS Receiver (Requires Anritsu GPS
Antenna)
S332E-0090 S362E-0090 Gated Sweep
S331E-0098 S332E-0098 S361E-0098 S362E-0098
Standard Calibration to
(ANSI 2540-1-1994)
S331E-0099 S332E-0099 S361E-0099 S362E-0099
Premium Calibration to Z540 plus test
data
S331E-0411 S332E-0411 S361E-0411 S362E-0411 Ethernet Connectivity
S332E-0431 S362E-0431 Coverage Mapping
(2)
S332E-0509 S362E-0509 AM/FM/PM Analyzer
S331E-0751 S332E-0751 S361E-0751 S362E-0751 CPRI RF Measurements
Note
Anritsu recommends allowing the instrument to warm up to typical operation
temperature (approximately 15 minutes) before calibrating.

Table of Contents

Other manuals for Anritsu s331c

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Anritsu s331c and is the answer not in the manual?

Anritsu s331c Specifications

General IconGeneral
BrandAnritsu
Models331c
CategoryMeasuring Instruments
LanguageEnglish

Related product manuals