EasyManua.ls Logo

Argo-Hytos OPCom - 23. Technical data; 23.1 Technical data table

Argo-Hytos OPCom
69 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Subject to change · V 2.02.20 · EN
Page 64
www.argo-hytos.com
23. Technical data
23.1 Technical data
Sensor data Size Unit
Max. operating pressure
dynamic 420 bar
static 600 bar
Permissible flow rate 50...400 ml/min
Operating conditions:
Temperature -20...85 °C
Rel. humidity
(non-condensing)
0...100 % r.H.
Display readable up to 60 °C
Compatible fluids Mineral oils (H, HL, HLP, HLPD, HVLP), synthetic esters (HETG, HEPG, HEES, HEPR),
polyalkylenglycols (PAG), zinc and ash-free oils (ZAF), polyalphaolefins (PAO)
Wetted materials Stainless steel, sapphire, chrome, NBR, minimess coupling: Zinc / nickel
Protection class
1)
IP67
Power supply 9...33 V
Power input max. 0,3 A
Max. power consumption 2 W
Output
Power output
2)
4...20 mA
Accuracy power output
3)
±2 %
Interfaces RS232 / CAN -
Alarm contact Open Collector -
Digital input for start and stop
Power supply 9...33 V
Data memory 3000 data records
Connecting dimensions
Fluid connections G¼ minimess M 16x2 inch
Electrical connection M 12 x 1, 8-pole -
Tightening torque
M12 - connection
0,1 Nm
Measuring range acc. to ISO 4406:17
Cleanliness level (measuring range) 0...24 Ordinal number (OZ)
Cleanliness level
(calibrated range)
10...22 Ordinal number (OZ)
Measuring accuracy
(calibrated range)
±1 Ordinal number (OZ)
Weight ~720 g
Table 44: Technical data
1)
With screwed-on connector
2)
Output IOut is freely configurable (see interfaces and communication commands)
3)
In relation to the analogue current signal (4 ... 20 mA)