Chapter 3 – Start-up and settings
UM-23100B-U User manual ATEQ F CLASS Page 28/90
3. DUPLICATION OF A TEST PROGRAM
To modify the parameters, turn the
key to the ACCES position.
Starting from the main menu, position
the cursor in front of the
PARAMETERS function.
RUN PROG.: 001
PARAMETERS
SPE CYCLE :Disabled
Confirm with the ENTER key. The
cursor will appear in front of the
Copy-Paste function. Confirm the
function again using the ENTER key.
Copy-Paste
Pr :001 ENGINE
Pr :002 HEAD
Next, confirm the COPY function.
PARAM/Copy-Paste
COPY :Pr ---
PASTE :Pr ---
Display the number of the program to
be copied using the navigation keys.
(In this case, program no.1). Confirm
using the ENTER key.
e
COPY :Pr 001
PASTE :Pr ---
Placer the cursor in front of Paste.
e
COPY :Pr 001
PASTE :Pr ---
Confirm with the ENTER key. Assign
a number to this new program using
the navigation keys (For example
no.3).
e
COPY :Pr 001
PASTE :Pr 003
Confirm with the ENTER key,
The display confirms that the program
has been copied.
COPY IN PROGRESS
The program no.1 parameters have
now been copied into program no.3
parameters. In this example program
no.3 is an exact copy of program n°1.
PARAM/Copy-Paste
COPY :Pr 001
PASTE :Pr 003
Press the CANCEL key twice to
return to the main menu.
C
C
MAIN MENU
PARAMETERS
SPE CYCLE:Disabled
CONFIGURATION