PARAMETER
DESCRIPTION
Job Order
- Fixed: The Steps of the Job are executed in the order specified in the window above.
- Free: The Steps of the Job are executed according to the Optional Trigger
defined in the Step parameter. The Optional Trigger is a barcode string that
must be scanned before executing the step.
See below for further details about the Step parameters.
NOK Strategy
- Abort: If a Step is executed with Not OK result, the Job is aborted.
- Continue: If a Step is executed with Not OK result, the Job continues.
Timeout (s)
Maximum time (in seconds) to complete the Job. If it is equal to zero there is no
control on the time. By default it is set on 120 seconds
Lock After Job
Done
If enabled, the MWR-TA is locked at the end of the Job (the Job must start again to continue).
If disabled, a new Job starts automatically when the previous Job is complete.
NOTE: The total number of Jobs is equal to 1000. They are distributed as follows: 300 Jobs for
Station 1, 300 Jobs for Station 2 and 400 Jobs for global (shared between Stations).
At the end of the configuration, click Save.
NOTE: Save icon is disabled if there are no steps in the Job.
To add a Step, enter the parameters in the Add Step area and click Add Step:
PARAMETER
DESCRIPTION
Name
Step name
Wrench
Select the MWR-TA from the list of MWR-TA associated with the Station
Batch Size
Number of times/bolts that the Step works
Infinite Batch Size
Selecting Infinitive batch Size option, the Step works an infinite number of
times/bolts. This option disables “Batch size” setting
Max NOK
For each tightening of the batch, it specifies how many times the operator can
execute a test with Not OK result
For instance, if it is set to 2, the operator can repeat two times a wrong tightening;
at the 3
rd
Not OK, the batch stops and the Job continues or aborts depending from
the NOK Strategy parameter defined in the Job
Infinite Max NOK
Selecting Infinitive Max NOK option specifies that the operator can execute a
test with Not OK result infinitely. This option disables Max NOK” setting
Timeout
Maximum time (in seconds) to start the Step from the moment the MWR-TA is ready to start
NOTE: The maximum permitted number of Steps (per Job) is equal to 100.