Focus 60 / Focus 61 User Guide Working with Open Protocol
9839 0211 01 Edition 1.1 95 (106)
11.1 Getting Result via Atlas Open Protocol
By the message MID 0001 Communication start”, a third application can start to communicate via
Atlas Open Protocol with the Focus 61; the reply (MID 0002) contains the basic information about the
controller.
Through the message MID 0060 Last tightening result data subscribe”, it is possible to make a
subscription.
NOTE: It is MANDATORY to specify into the message MID 0060 the Station ID (0 or 1).
From the subscription, all the tightening results performed will be sent to the Atlas Open Protocol
application automatically by the message MID 0061.
NOTE: When the application does not want any further data from the Focus 61, it sends to the
controller the message “MID 0063- Last tightening result data unsubscribe”.