Focus 60 / Focus 61 User Guide Working with Open Protocol
9839 0211 01 Edition 1.1 97 (106)
11.2 Starting a Job via Atlas Open Protocol by means of
VIN or Identifier
By the message “MID 0001 Communication start”, the Atlas Open Protocol starts to communicate with
the Focus 61; the reply (MID 0002) contains the basic information about the controller.
Through the message MID 0050 Vehicle ID Number download request, it is possible to trigger an
event (configured in the Focus 61) in order to start a Job.
NOTE: It is MANDATORY to specify into the message MID 0050 the Station ID (0 or 1).
Before sending this message from the Atlas Open Protocol to the Focus 61, there are some mandatory
steps to satisfy.
First, configure a Job to associate with the Event (refer to the paragraph “Job Configuration”).
Second, configure an Event:
- Event Type must be either AOP_SETVIN
- Station action must be set on Enable Station
- Job action must be set on Start Job (thus select the Job previously configured)
- Barcode action must be set on Station_IDN
After configuring both a Job and an Event, when the Atlas Open Protocol sends a message MID 0050
Vehicle ID Number download request to the Focus 61, this receives a VIN and verifies that it matches
with the Pattern configured; if it is, the Job starts and the Blue LED on the MWR-TA starts to blink.
Atlas Open
Protocol
First Step
MID 0001 Communication start
MID 0002
Second
Step
Third
Step
MID 0050 Vehicle ID Number download
request
JOB STARTS