Executing Tightening Operations Focus 60 / Focus 61 User Guide
78 (106) 9839 0211 01 Edition 1.1
The Focus 60 / Focus 61 display shows the tightening result of the last tightening:
Refer to the following results status list for possible results status that can be shown on the Focus 60 /
Focus 61 display:
OK = Torque and angle within the limits (OK)
NOK = Torque and angle above the limits (Not OK)
LCK = Wrench locked
ANOK = Torque and angle below the limits (Not OK)
BNOK = Torque below the limits, angle within the limits (Not OK)
CNOK = Torque below the limits, angle above the limits (Not OK)
DNOK = Torque within the limits, angle above the limits (Not OK)
ENOK = Torque within the limits, angle below the limits (Not OK)
FNOK = Torque above the limits, angle below the limits (Not OK)
GNOK = Torque above the limits, angle within the limits (Not OK)
ROK = Existing fitting (double hit), torque within the limits
RNOK = Existing fitting (double hit), torque above the limits
NEG = False direction of tightening (loosen)
OVSC = Additional torque limit overload screw exceeded
OVLD = Overload value of the wrench exceeded! Check calibration urgently!
TNOK = Timeout expired, torque / angle are not OK
TOK = Timeout expired, torque / angle are OK
OVAR = Maximum angular speed exceeded / it needs to be calibrated (Not OK)
OVAD = Reading outside of the AD converter range (Not OK)
Torque peak
Torque click
Angle
Status
Batch counter
MWR-TA
serial number

Table of Contents