Live Monitor Focus 60 / Focus 61 User Guide
82 (106) 9839 0211 01 Edition 1.1
Hereunder are the fields displayed in the above Result Monitor screen:
FUNCTION
DESCRIPTION
Wrench serial number
Serial number of the MWR-TA
#
Result ID
IDN1: IDN2: IDN3:
IDN defined in the Job
NOTE: If the ToolsTalk BLM is connected, the IDN is NOT
visible.
Export Results
This option exports in an Excel file the results displayed in a tightenings session
Batch Size, Max NOK
Pset parameters set for the MWR-TA
OK, NOK
Number of tightening operations with OK and Not OK results
Torque result and Angle
Result
Peak and click torque/angle values of the last tightening operation.
The boxes are green colored if the torque/angle peaks are between the
minimum and maximum values defined in the MWR-TA Pset; otherwise
they are red colored
Torque Status and Angle
Status
This box shows the status and the limits defined in the MWR-TA Pset.
The status can be:
- Waiting…: Live results monitor open, but no results available yet
- Low: Torque/Angle lower than the minimum value
- OK: Torque/Angle within the limits
- High: Torque/Angle higher than the maximum value
Status
Overall status of the tightening operation.
Refer to the paragraph Executing Tightening Operations for further
details about the code shown here.
The box is green if the Status is OK, yellow if the MWR-TA is locked,
red if the Status is Not OK.
Timestamp
Date and time
NOTE: In case two MWR-TA on two different stations generate a result at the same time, only
the last one is visible on the Live Monitor interface.