4. Once the stabilizers (3) have been extended,
release the locking pin (1) to lock them in
position.
5. Turn the handle (4) at the top of the supporting
feet anticlockwise to lower them and put the light
tower in a level position.
6. Once the light tower is correctly positioned, install
a suitable earthing (e.g. the optional earth pin (6))
and make sure that it is correctly connected to the
light tower (7).
For more detailed installation instructions, see also
chapter “Installation” on page 26.
Adjust the height of the supporting
feet gradually in order to ensure the
stability of the unit.
Check the levels (5) on top of the
light tower to ensure that the unit is
in a level position.
5
6
7