To enable automatic mast operation, proceed as
follows:
1. Put the starter switch S20 in position REMOTE
(1).
2. Switch ON the 4 circuit breakers (Q2-5) (2).
3. Put the auto positioning switch S25 in position
AUTO (3).
4. Push the AUTO button on the Lc1003™ module
(4) to activate AUTO mode.
5. A remote start signal (Sunset or Weekly timer
start) will trigger the following actions:
Start engine
Activate buzzer
•Rise mast
Sequence lamp start
6. A remote stop signal (Sunrise or Weekly timer
stop) will trigger the following actions:
Sequence lamp stop
Activate buzzer
•Lower mast
Stop engine
7.4.4 Auto tilt
The auto tilt option allows to set the inclination angle
of the floodlights via the control panel.
S30 .....Auto tilt switch
Turn the switch to UP to increase the
inclination angle of the floodlights.
Turn the switch to DOWN to decrease the
inclination angle of the floodlights.
P9........ Actuator DC supply and control
7.4.5 MSA connector
The MSA connector is located in the cubicle and
allows remote emergency stops.
X19 .....MSA connector
L
c
1003
0
1
0
DO
UP
MAN
AUTO
0
1
K5
P9
S30
P9
L
c
1003
0
1
0
DO
UP
MAN
AUTO
0
1
X19
00_00_HiLight B6+_EN.book Page 75 Thursday, September 2, 2021 11:50 AM