ABLEPick pick-to-light communication protocol
64
Bit 0 Input Voltage too low
Bit 1 Input Voltage too high
Bit 2 reserved
Bit 3 reserved
Bit 4 reserved
Bit 5 reserved
Bit 6 reserved
Bit 7 System abnormal
DATA[2~9] = Reserved
6.3 Enable/Disable the alarm auto-report function
If any alarm status is changed, the AT400 can send the alarm status message
automatically (Default: Disable the alarm auto-report function) . The status message format
is the same as the return message of the 'Read alarm status' command
SUB-COMMAND = F7H
CCB Description
CCB LEN(L)= 0AH
Length of CCB = 10 bytes
CCB LEN(H) =00H
MESSAGE TYPE = 60H
60H: port1 of controller,
Reserved
Reserved
Reserved
SUB-COMMAND
F7H
SUB-NODE
00H
Message Type
01H : Set/Get the alarm auto-report
mode
Data(0)
Mode type
DATA[0] = Set/Get the alarm auto-report mode
00H Get the alarm auto-report mode
01H enable the alarm auto-report mode
02H disable the alarm auto-report mode
6.3.1 Return the alarm auto-report mode
SUB-COMMAND = F7H
CCB Description
CCB LEN(L)= 0AH
Length of CCB = 10 bytes
CCB LEN(H) =00H
MESSAGE TYPE = 60H
60H: port1 of controller,
Reserved
Reserved
Reserved
SUB-COMMAND
F7H
SUB-NODE
00H
Message Type
01H : Get the alarm auto-report
mode
Data(0)
Mode type
DATA[0] = Get the alarm auto-report mode
00H the alarm auto-report mode is disabled
01H the alarm auto-report mode is enabled