ABLEPick pick-to-light communication protocol
34
In general mode, when device be pushed the confirmation button, the display
will be off, nothing left on it. Enable this bit, it will display “-----“ instead of off
after confirmation.
Note (4) : Bit 3 : device self-testing function
.Enable/disable device’s self-testing function, described in ABLEPick user
manual.3.2.1.5
Note (5) : Bit 4 : Cycle edit function
In general mode, the maximum value you can adjust by up-count/down-count
button is always equal to the original sending value, no more than it. Enable this
bit, user can adjust the quantity to be more than the original sending value.
This function only can be applied on AT505 V1.2 & AT705 above, when it is
enabled, the LED light & display will be blinking all the way.
This bit is valid only when the tag mode’s bit 2 (up-count/down-count) is
enabled.
When this bit has been enabled, the sub-command of return message is 24H
instead of 06H
4.3.21 Get device’s F/W model information
Asking the device to return its F/W model number.
SUB-COMMAND = FAH
CCB LEN (L) = 08H
Data length of this block
CCB LEN (H) = 00H
MESSAGE TYPE = 60H
60H : port 1
Reserved
Reserved
Reserved
SUB-COMMAND = FA H
SUB-NODE = {01H ~ FAH}
0x01~0xFA (address)
or 0xFC (Broadcasting)
Note : The function only can be applied on AT505 V1.2 above
Some models share the same F/W, then the return F/W model name will be
the same, for example, AT705, AT703, AT702, AT70N, AT706 share the same
F/W version, then the return model name is always “AT705” instead.
4.3.22 Get device’s detail configured information
Get device’s detail information
SUB-COMMAND = FCH
CCB LEN (L) = 08H
Data length of this block
CCB LEN (H) = 00H
MESSAGE TYPE = 60H
60H : port 1
Reserved
Reserved
Reserved
SUB-COMMAND = FC H
SUB-NODE = {01H ~ FAH}
0x01~0xFA (address)
or 0xFC (Broadcasting)