the measured value block signal is displayed as a duty cycle (e.g. for 1.61 aluminium engine in measured
value block 57, display zone 4).
=> Relevant Workshop Manual Injection and Ignition system
If within one driving period an excessively high pressure is measured 30 times in the refrigerant circuit and
the compressor (magnetic clutch -N25) is switched off by operating and display unit -E87, the compressor
no longer switches on automatically. The compressor can be switched on again by actuating the "Com‐
pressor on" button or by switching the ignition off and on again. If this fault occurs over several driving cycles,
the compressor cannot be switched on again until the fault memory has been erased.
V.A.G 1551 printer Possible causes of fault Fault remedy
00796 3234
Dash panel temperature sensor
blower -V42
* Blocked or de-energised /SP
- Open circuit in the power supply
to -V42 or in the wiring between -
V42 and -E87.
Blower -V42 defective.
- Locate and eliminate the open cir‐
cuit using the current flow diagram
Replace blower -V42.
00797 3241
Sunlight penetration photo sensor -
G107
* Open circuit/short to
positive /SP
* Short to earth /SP
- Short circuit or open circuit be‐
tween -G107 and -E87.
Photosensor -G107 defective.
- Use current flow diagram to locate
and eliminate short circuit, open cir‐
cuit in wiring or fault in pin assign‐
ment.
Replace photosensor -G107 .
00818
Evaporator outlet temperature send‐
er -G263
* Short to earth /SP
* Open circuit/short to
positive /SP
- The sender -G263 is not installed
in the Audi A3 at the moment.
Short circuit to connector B contact
15 at -E87.
- Use current flow diagram to locate
and eliminate short circuit
Notes:
With operating and display units -E87 with one display the blower -V42 is installed into -E87.
The fault "sender for ambient temperature evaporator -G263" can only be displayed by an operating and
display unit -E87 with one display.
V.A.G 1551 printer Possible causes of fault Fault remedy
Operating and display unit up to index "E" (two displays)
01044
Control unit incorrectly encoded
- Proper encoding procedure for -E87
was not followed
Wrong code was entered
- Code operating and display unit -E87
as specified =>Page 27
(cont.)
Note:
The faults "Control unit incorrectly encoded" and "Basic setting not performed" are not stored by all operating
and display unit versions (operating and display units that store these faults are gradually introduced as of
Model Year 1999).
V.A.G 1551 printer Possible causes of fault Fault remedy
(cont.)
Operating and display unit -E87 with index "M" or "N" (two displays)
Audi A3 1997
Heating, Air Conditioner - Edition 06.2000
14 01 - Self-diagnosis, Electrical check