EasyManua.ls Logo

Audi A3 1997 - Reading Measured Value Block

Audi A3 1997
241 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Protected by copyright. Copying for private or commercial purposes, in part or in whole, is not
permitted unless authorised by AUDI AG. AUDI AG does not guarantee or accept any liability
with respect to the correctness of information in this document. Copyright by AUDI AG.
Assignment of operating and display unit
-E87.
=> Parts List
9 - Reading measured value block
9.1 - Reading measured value block
Notes:
10 measured value blocks with 4 measured values each are intended for operating and display units -E87
with two displays.
12 measured value blocks with 4 measured values each are intended for operating and display units -E87
with one display.
The AC control function remains switched on during self-diagnosis (function "Reading measured block val‐
ue") and the current measured values are displayed.
Display groups 2 to 5 show the currently valid actual/specified value or the value learnt and stored during
the last basic setting for the end stops of the individual positioning motors.
The position of the positioning motors, and therefore of the flaps, can be changed during the self-diagnosis
using the controls on
-E87, and the current actual and specified values can be displayed directly on the fault reader.
If the printer is switched on, the current display will be recorded in the form of a printout.
Starting "Reading measured value block"
- Start engine.
- Set "AUTO" mode on operating and display unit -E87 (compressor is switched on).
- Run fresh air blower for approx. 1 minute at high speed (to adjust the positioning motors).
- Connect up fault reader V.A.G 1551, enter address word 08 "Electronic climate/heating control" and advance
the program until "Select function XX" appears on display => Page 4 onwards.
-> Indicated on display (function selection):
Rapid data transfer HELP
Select function XX
- Press keys -0- and -8- (08 selects the "Reading measured value block" function.)
-> Indicated on display:
Rapid data transfer Q
08 - Reading measured value block
- Press Q to confirm entry.
-> Display:
Reading measured value block
Enter display group number XXX
- Enter display group number (overview =>Page 32 ).
- Press Q to confirm entry.
-> Indicated on display:
Reading measured value block X
1 2 3 4
To select another display group:
- Press C key.
-> Indicated on display:
Audi A3 1997
Heating, Air Conditioner - Edition 06.2000
8.3 - Coding of operating and display unit with one display 31

Table of Contents

Other manuals for Audi A3 1997

Related product manuals