Test step Component tested Page
5 - Air conditioner pressure switch -F129 /
Signal from control unit for radiator fan -J293.
Temperature sensor blower -V42.
"Air conditioner compressor cut-in" output.
Signal "Engine temperature too high".
55
6 - Actuation of air conditioner magnetic clutch -N25.
Actuation of radiator fan -V7
58
Test step 1
Power supply, earth connection and illumination of operating and display unit -E87.
Select measuring range on hand-held multimeter V.A.G 1526:
Voltage measurement (20V =)
- Adapter cable V.A.G 1598/12 connected
Test step V.A.G 1598
socket
Testing of ▪ Test conditions
- Additional opera‐
tions
Specified value Remedies if speci‐
fied value not at‐
tained
1.1 9
and
15
Terminal 15 and
earth connection
on -E87
▪ Ignition on - Approx. battery
voltage
- Use current flow di‐
agram to repair
power supply and/or
earth connection
Select measuring range on hand-held multimeter V.A.G 1526:
Voltage measurement (20V =)
- Adapter cable V.A.G 1598/11 connected
1.2 7 and
earth
Terminal 58 on -
E87
▪ Ignition on.
▪ Switch side lights
on
- Approx. battery
voltage
- Use current flow di‐
agram to repair
power supply
Notes:
Test steps 1.3 to 1.5 must be implemented only for model year 1997 vehicles (operating and display unit
with part no. 8L0 820 043 up to and including index "C").
Earth applied e.g. to connector D contact 15.
Select measuring range on hand-held multimeter V.A.G 1526:
Voltage measurement (20V =)
- Adapter cable V.A.G 1598/11 connected
Test step V.A.G 1598
socket
Testing of ▪ Test conditions
- Additional opera‐
tions
Specified value Remedies if speci‐
fied value not at‐
tained
1.3 7 and
earth
Terminal 58 on -
E87
▪ Ignition on
▪ Side lights off
- less than 2 V - Use the current
flow diagram to rec‐
tify short to positive
1.4 45 and
earth
Terminal 58d on -
E87
▪ Ignition on
▪ Side lights on
- 0 to 12 V (regard‐
less of the illumina‐
tion control setting)
- Use current flow di‐
agram to locate and
eliminate open cir‐
cuit or short circuit
Audi A3 1997
Heating, Air Conditioner - Edition 06.2000
10.3 - Test in vehicles with an operating and display unit with two displays 49

Table of Contents