Select measuring range on hand-held multimeter V.A.G 1526:
Current measurement (20 A=)
3.2 Connector
A contact 4
and
connector
A, contact
12
Signal for "Refrig‐
erant circuit pres‐
sure OK" to -E87
▪ Engine running
▪ The fault reader
V.A.G 1551 remains
connected.
▪ The self-diagnosis
for the air conditioner
(address word "08")
is initiated.
▪ The display group
"001" is selected in
the function "read
measured value
block".
Press "Auto"-key on
-E87.
- Less than 1 A
"0" is displayed in
the measured value
block of -E87 (dis‐
play group "001",
display zone "1")
- Use current flow di‐
agram to locate and
eliminate open cir‐
cuit or short to posi‐
tive or earth in the
wiring between con‐
trol unit -J293 and -
E87.
Eliminate cause of
compressor shutoff
condition
Select measuring range on hand-held multimeter V.A.G 1526:
Current measurement (20 A=)
Test step Contact at
connector
to -J293
Testing of ▪ Test conditions
- Additional opera‐
tions
Specified value Remedies if speci‐
fied value not at‐
tained
3.3 Connector
A contact 6
and
connector
A, contact
12
Signal for "Refriger‐
ant circuit pressure
NOK" to -E87
▪ Engine running.
▪ The fault reader
V.A.G 1551 remains
connected.
▪ The self-diagnosis
for the air condition‐
er (address word
"08") is initiated.
▪ The display group
"001" is selected in
the function "read
measured value
block".
- Less than 1 A
"1" is displayed in
the measured value
block of -E87 (dis‐
play group "001",
display zone "1")
- Use current flow di‐
agram to locate and
eliminate open cir‐
cuit or short to posi‐
tive in the wiring be‐
tween control unit -
J293 and -E87.
Select measuring range on hand-held multimeter V.A.G 1526:
Current measurement (20 A=)
Test step Contact at
connector to -
J293
Testing of ▪ Test conditions
- Additional opera‐
tions
Specified value Remedies if specified
value not attained
3.4 Connector A
contact 4
and
connector A,
contact13
Connection to input
for "Refrigerant tem‐
perature too high"
recognition
▪ Ignition on. - 0 A - Rectify short circuit
to earth in connector
A contact 13.
Notes:
The contact 13 in connector -A- is not occupied in all vehicles. Switching off of the compressor when re‐
frigerant temperature is too high occurs via the operating and display unit -E87 in vehicles in which the
contact is not occupied (if the contact is occupied switching off occurs simultaneously via -E87 and -J293).
If earth is applied to connector -A- contact 13, the radiator fans are actuated and the compressor is not
switched on.
Select measuring range on hand-held multimeter V.A.G 1526:
Voltage measurement (20V =)
Bridge at connector A between contact 4 and contact 12
Audi A3 1997
Heating, Air Conditioner - Edition 06.2000
82 01 - Self-diagnosis, Electrical check