CHAPTER2 SNMP Trap Alarms
MSBR | SNMP Alarms
Active Alarm Table Alarm
Table 2-35: acActiveAlarmTableOverflow
Alarm acActiveAlarmTableOverflow
OID 1.3.6.1.4.15003.9.10.1.21.2.0.12
Description The alarm is sent when an active alarm cannot be entered into the Active
Alarm table because the table is full.
Default
Severity
Major
Source
Varbind Text
System#0<n>/AlarmManager#0
Event Type processingErrorAlarm
Probable
Cause
resourceAtOrNearingCapacity (43)
Alarm Severity Condition Text Corrective Action
Major Too many
alarms to
fit in the
active
alarm table
"Active
alarm table
overflow"
■ Some alarm information may be lost
but the ability of the device to perform
its basic operations is not impacted.
■ A reboot is the only way to completely
clear a problem with the active alarm
table.
■ Contact AudioCodes Support.
Remains
'Major' until
reboot. A
'Clear' trap is
not sent.
After the
alarm is
sent
- Note that the status remains 'Major' until
reboot as it denotes a possible loss of
information until the next reboot. If an
alarm is sent when the table is full, it is
possible that the alarm is active, but does
not appear in the active alarm table.
Analog Port Alarms
Analog Port SPI Out-of-Service Alarm
The alarm is applicable only to analog interfaces.
- 47 -