CHAPTER2 SNMP Trap Alarms
MSBR | SNMP Alarms
Clock Configuration Alarm
Table 2-27: acClockConfigurationAlarm
Alarm acClockConfigurationAlarm
OID 1.3.6.1.4.1.5003.9.10.1.21.2.0.149
Description The alarm is sent when device clock synchronization by NTP server
and SIP Date header (in response message to SIP REGISTER) are both
enabled. In this configuration scenario, NTP is used as the source of
the clock synchronization.
Default Severity Minor
Source Varbind
Text
Board#1
Event Type operationalViolation
Probable Cause configurationOrCustomizationError
Alarm Text Board Configuration Error: DateHeaderTimeSync would be ignored as
NTP is enabled.
Severity Condition Text Corrective Action
Minor Clock
synchronization by
NTP and SIP Date
header are both
enabled.
"Clock
Synchronization
from SIP Date
header ignored as
NTP is enabled"
Disable one of the
clock
synchronization
methods.
Cleared One of the clock
synchronization
methods is disabled.
- -
NTP Server Status Alarm
Table 2-28: acNTPServerStatusAlarm
Alarm acNTPServerStatusAlarm
OID 1.3.6.1.4.1.5003.9.10.1.21.2.0.71
Description The alarm is sent when the connection to the NTP server is lost.
Cleared when the connection is reestablished. Unset time (because
- 41 -