CHAPTER2 SNMP Trap Alarms
MSBR | SNMP Alarms
Alarm acNFASGroupAlarm
out-of-service when the backup Non-
Facility Associated
Signaling (NFAS) D-
channel also falls, i.e.,
when both D-channels
are down.
When at least one of
the
D-channels (primary or
backup) returns to
service, the alarm is
cleared.
Corrective action is not
necessary.
Clear NFAS group
state goes to
in- service
"%s– Additional
information"
-
Board Alarms
The source varbind text for all alarms under this component is System#0<n>, where n is the slot
number in which the blade resides in the chassis.
Fatal Error Alarm
Table 2-9: acBoardFatalError
Alarm acBoardFatalError
OID 1.3.6.1.4.1.5003.9.10.1.21.2.0.1
Description The alarm is sent whenever a fatal device error occurs.
Default Severity Critical
Event Type equipmentAlarm
Probable Cause underlyingResourceUnavailable (56)
Severity Condition Text Corrective Action
Critical Any fatal
error
"Board Fatal Error: A
run-time specific
1. Capture the alarm inform-
ation and the Syslog clause,
- 17 -