CHAPTER2 SNMP Trap Alarms
MSBR | SNMP Alarms
Alarm acBoardConfigurationError
in Critical severity until a
device reboot. A Clear
trap is not sent.
After
configuration
error
-
Software Reset Alarm
Table 2-12: acBoardEvResettingBoard
Alarm acBoardEvResettingBoard
OID 1.3.6.1.4.1.5003.9.10.1.21.2.0.5
Description The alarm is sent after the device resets.
Default
Severity
Critical
Event Type equipmentAlarm
Probable
Cause
outOfService (71)
Severity Condition Text Corrective Action
Critical When the device is
reset through the
Web interface or
SNMP
"Device is
resetting"
A network administrator has reset
the device. Corrective action is
not required.
The alarm remains at Critical
severity level until the device
completes the reboot. A Clear
trap is not sent.
Software Upgrade Alarm
Table 2-13: acSWUpgradeAlarm
Alarm acSWUpgradeAlarm
OID 1.3.6.1.4.1.5003.9.10.1.21.2.0.70
Description The alarm is sent when an error occurs during the software upgrade
process.
Default Major
- 20 -

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the AudioCodes MSBR Series and is the answer not in the manual?

AudioCodes MSBR Series Specifications

General IconGeneral
BrandAudioCodes
ModelMSBR Series
CategorySecurity System
LanguageEnglish

Related product manuals