CHAPTER2 SNMP Trap Alarms
MSBR | SNMP Alarms
Alarm acBoardWanLinkAlarm
Default Severity Major / Clear
Event Type equipmentAlarm
Source Varbind
Text
Board#x/WanLink#y
Probable Cause underlyingResourceUnavailable
Severity Condition Text Corrective Action
Major WAN link down - Connect the WAN
port
Clear WAN link up - -
Wireless Cellular Modem Alarm
Table 2-31: acWirelessCellularModemAlarm
Alarm acWirelessCellularModemAlarm
OID 1.3.6.1.4.1.5003.9.10.1.21.2.0.82
Description The alarm is sent when either the wireless modem is down or in backup
mode, and cleared when modem is up.
Default
Severity
Major / Clear
Source
Varbind Text
Board#x/WanLink#y
Event Type equipmentAlarm
Probable
Cause
underlyingResourceUnavailable
Severity Condition Text Corrective Action
Major The wireless modem is
down or in backup
mode, and cleared
when modem is up.
"WAN
wireless
cellular
modem
alarm"
Get the link up. Investigate the
possibility of an electronics
failure or a problem with the
radio frequency (RF) path.
- 44 -

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the AudioCodes MSBR Series and is the answer not in the manual?

AudioCodes MSBR Series Specifications

General IconGeneral
BrandAudioCodes
ModelMSBR Series
CategorySecurity System
LanguageEnglish

Related product manuals