CHAPTER2 SNMP Trap Alarms
MSBR | SNMP Alarms
Alarm acNoReplyFromDNSServerAlarm
address of the DNS
server is correct.
Cleared Response received
from DNS server.
- -
Configuration Error Alarm
Table 2-11: acBoardConfigurationError
Alarm acBoardConfigurationError
OID 1.3.6.1.4.1.5003.9.10.1.21.2.0.2
Description The alarm is sent when the device's settings are invalid. The trap
contains a message stating, detailing, and explaining the invalid
setting.
Default Severity Critical
Event Type equipmentAlarm
Probable Cause underlyingResourceUnavailable (56)
Severity Condition Text Corrective Action
Critical A configuration
error was
detected
"Board Config
Error: A run-time
specific string
describing the
configuration
error"
a. Check the run-
time specific
string to determ-
ine the nature of
the configuration
error.
b. Fix the con-
figuration error
using the appro-
priate tool: Web
interface, OVOC,
or ini file.
c. Save the con-
figuration and if
necessary reset
the device.
Note: The alarm remains