CHAPTER2 SNMP Trap Alarms
MSBR | SNMP Alarms
Trunk AIS Alarm
Table 2-3: acTrunksAlarmRcvAIS
Alarm acTrunksAlarmRcvAIS
OID 1.3.6.1.4.1.5003.9.10.1.21.2.0.51
Source
Varbind
Text
Interfaces#0/Trunk#<m>, where m is the trunk interface number, 1 being
the first trunk
Alarm Text communicationsAlarm
Event Type PSTN provider has stopped the trunk (receiveFailure)
Probable
Cause
communicationsAlarm
Severity Condition Text Corrective Action
Critical Receive AIS "Trunk AIS
Alarm"
1. Contact your PSTN provider to
activate the trunk.
2. If the alarm persists, contact
the AudioCodes Support.
Cleared End of AIS - -
Trunk Far-End LOF Alarm
Table 2-4: acTrunksAlarmFarEndLOF
Alarm acTrunksAlarmFarEndLOF
OID 1.3.6.1.4.1.5003.9.10.1.21.2.0.52
Default
Severity
Critical
Source
Varbind Text
Interfaces#0/Trunk#<m>, where m is the trunk interface number, 1 being
the first trunk
Event Type communicationsAlarm
Probable
Cause
transmitFailure